ACORD-Express: Hinged Joints   ACORD-Express: Hinged Joints
The aim is to check the constructive provisions and the strength criteria of lap and hinged joints.
General input data
In first instance you choose the configuration to be considered (in a total of 25) according to the continuity of the assembled pieces, the number of shear planes (1 or 2), the alignment of pieces and the materials (wood-wood or wood-metal). Then, regarding the type of fasteners, are available: bolts, nails, hooks, rings and dowels. Please note that up to 5 fasteners can be installed and that the wood ends can be either normal or parallel.

In any case, you must complete the input data with:
  • Environmental parameters (moister content, …)
  • Wood category
  • Dimensions of the members and of the fasteners
  • Loads (up to 10 loads, each criterion will be determined on the envelop of the defined load cases)
Overview on the design report
ACORD-Express: Hinged Joints
The created design report has the following sections:
  • Loading parameter definition
  • Definition of parameters and coefficients regarding the material and the environment (strength, partial coefficients, modification coefficients, etc.)
  • Definition of the dimensions of the members
  • Definition of the fasteners
  • Check of the fastener spacing
  • Check of the strength of the fasteners
  • Check of the wood pieces to normal tension
  • Check of the reduced cross-section.
haut de page